Guide · Lighting know-how

Lumens per m²: the table for every room

“How many lumens do I need for 20 m²?” is the most practical way to ask the lighting question — because lumens are printed on every box. The link to the lux guide values is a single division. Here’s the table for all common rooms, plus the conversion so you can work out any special case yourself.

Table: lumens per square metre by room type

Calculated from the usual target lux values with a utilisation factor of 0.6 (lumens ÷ m² of installed luminaire lumens):

RoomGuide value
Bedroom, living room general lighting (100–150 lx)170–250 lm/m²
Hallway, staircase (100 lx)170 lm/m²
Kitchen, bathroom general lighting (200–300 lx)330–500 lm/m²
Kitchen worktops / hobby areas (300–500 lx)500–850 lm/m²
Office workstations (500 lx)850 lm/m²
Workshop (300 lx) / warehouse (150–200 lx)600 / 300–400 lm/m²

The conversion behind it: lux is lumens per square metre — but measured where the light arrives on the surface, not at the luminaire. Between luminaire and floor, 30–50% is lost to light spilling onto walls, reflection losses and ageing. So: installed lm/m² = target lux ÷ 0.5…0.7.

The factor depends on the room: light-coloured walls and a normal ceiling height → 0.7; dark furnishings, a high ceiling or lots of furniture → closer to 0.5. For quotes, 0.6 is the robust middle ground.

Worked example: a 20 m² room from living space to office

The same room, three uses — this is how differently the lumen budget works out:

20 m² × target lux ÷ 0.6 = total lumens required

As a living room (120 lx): 4,000 lm — e.g. 5–6 downlights or 2 wall washers plus a floor lamp. As a kitchen (200 lx general + task lighting): 6,700 lm plus under-cabinet lights. As an office (500 lx): 16,700 lm — now we’re talking 4–5 LED panels at 3,600 lm each.

Same floor area, a factor of four in lighting demand: that’s why there’s no way around the room-type question — and why ‘X lumens per m²’ without stating the room type is no use as a recommendation.

The 3 most common mistakes when calculating lumens

  1. Treating lux and lumens as the same thing. 500 lm at the luminaire is not 500 lx on the desk. Lux measures what actually arrives — the room’s losses sit in between. Always calculate with a utilisation factor of 0.5–0.7.

  2. Trusting the manufacturer’s ‘replaces 100 W’ claim. Replacement claims are marketing with generous interpretation. The only binding figure is the lumen value on the data sheet — and for spots, the beam angle as well.

  3. Using one value for the whole house. 170 lm/m² for the bedroom, 850 for the home office — one blanket value across all rooms is either too dark or too expensive. Calculating room by room takes two minutes longer.

Check the layout instead of guessing

Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.

Frequently asked questions

How many lumens for 20 m²?
It depends on the use: as a living space roughly 4,000–5,000 lm, as a kitchen 6,000–7,000 lm plus task lighting, as an office around 17,000 lm. Formula: area × target lux ÷ 0.6.
How do I convert lux to lumens?
Required lumens = lux × area ÷ utilisation factor (0.5–0.7). The other way round: achieved lux ≈ installed lumens × utilisation factor ÷ area.
What’s the difference between lumens and lux?
Lumens describe how much light a luminaire emits; lux describes how much of it arrives on one square metre of surface. 1 lx = 1 lm/m² — measured on the illuminated surface.
Are more lumens always better?
No — in living spaces, too much light quickly tips into discomfort, and glare increases with it. The goal is the right value per zone, plus the ability to dim down.

Read on

All lux figures are guide values based on EN 12464-1 or common practice — a planning aid, not a normative proof. Professional review and execution remain the responsibility of the contractor.