Lighting design guide

Practical knowledge for electrical contractors: how much light each room needs, how to space luminaires and which mistakes to avoid. All values are guide values and a planning aid.

Lighting design by room

Workshop lighting design: lux levels, luminaire choice and a worked example

Plan workshop lighting: 300–500 lux by task area, IP65 LED battens vs high bays, shadow-free workbenches — with a worked example and common mistakes.

Warehouse lighting design: high bays, zones and racking aisles

Plan warehouse lighting: 100–300 lux per zone, high bays over racking aisles, worked example for 200 m² — plus typical high-ceiling mistakes.

Lighting design for a GP practice: from the waiting room to the treatment room

Plan medical practice lighting: 500 lux in treatment rooms, 1,000 lux at examination, 300 lux at reception, 200 in waiting rooms — with worked example.

Kitchen lighting design: worktops, island and under-cabinet lighting

Plan kitchen lighting: 300–500 lux on worktops, downlight layout without shadows, pendants over the island, LED strips under wall units — with example.

Bathroom lighting design: brightness, IP zones and the mirror

Plan bathroom lighting: 200–300 lux general, 500 lux at the mirror, IP zones 0/1/2 — worked example for an 8 m² bathroom and common mistakes.

Living Room Lighting Design: Pools of Light, Not a Supermarket Grid

Plan living room lighting: 100–150 lux ambient, pools of light for sofa, reading nook and TV — why the downlight grid is wrong. With worked example.

Bedroom lighting design: soft ambient light, bright where it matters

Plan bedroom lighting: 100 lux ambient light, 300 lux for reading, wardrobe lighting, warm colour temperature — with a worked example and common mistakes.

Lighting design for retail spaces: ambient light plus accents that sell

Plan shop lighting: 300 lux ambient, 3:1 accent contrast on goods, flexible track spotlights, shop windows — with a worked example for an 80 m² shop.

Restaurant lighting design: atmosphere out front, task lighting at the back

Plan restaurant lighting: 200 lux dining room with warm pools of light, 300 lux bar, 500 lux commercial kitchen — with worked example and common mistakes.

Stairwell lighting design: safe, sensor-controlled, low maintenance

Plan stairwell lighting: 100–150 lux, shadow-free step edges, presence detectors not timers, emergency lighting — with a block of flats example.

Lighting design for garages and hobby rooms: bright enough for more than parking

Plan garage lighting: 100–150 lux for parking, 300 lux at the workbench, IP-rated fittings and motion sensors — plus a double garage worked example.

Lighting design for hallways and entrance halls: the underrated first impression

Plan hallway lighting: 100 lux ambient light, downlight spacing, coat rack and mirror lighting — with worked example and common mistakes.

Lighting know-how

How Many Downlights Per Room? The Rule of Thumb with Table

Calculate how many downlights you need: area × lux ÷ 0.6 ÷ lumens, table for rooms from 8 to 40 m², plus the layout rules that matter more than quantity.

Lumens per m²: the table for every room

How many lumens per square metre? Table from bedroom (170 lm/m²) to office (850 lm/m²), the lux-to-lumen conversion and a worked example for your room.

Getting Downlight Spacing Right: Rules of Thumb That Work

Calculate downlight spacing: half to full ceiling height rule, wall distance, beam angle and cone diameter — with hallway, kitchen and lounge examples.

Colour temperature in Kelvin: which light colour goes where

Kelvin chart: 2,700 K living rooms, 3,000 K bathrooms, 4,000 K offices and workshops, 5,000+ K inspection — with rules for transitions and common mistakes.

Converting watts to lumens: the chart for everyday LED work

Watts no longer tell you brightness: conversion chart from incandescent/halogen to LED lumens, efficacy (lm/W) explained, plus worked examples.

How to calculate lux: the formula behind every lighting design

Calculate lux by hand: E = luminous flux × utilisation factor ÷ area, what’s behind the factor (reflectance, maintenance), worked example and limits.

UGR explained: what the glare rating actually means

What does UGR ≤ 19 mean? The UGR table for offices, industry and screen work, how to avoid glare without calculations and when formal proof is needed.

LED panel or downlight? How to decide in 60 seconds

Panel vs downlight: when area light wins (office, practice) and when spots do (home, hallway, accent) — comparison table, costs, common mistakes.

What Does a Lighting Design Cost? The Honest Price Comparison

Lighting design costs compared: design consultancies, pro software, wholesaler services and free tools — plus the hidden costs nobody factors in.

Planning LED Strips: Getting Lumens per Metre, Profile and Driver Right

Plan LED strips properly: lumens per metre by application, COB vs SMD, why the aluminium profile matters and how to size the PSU with headroom.

Dimming and lighting control: which technology suits which project?

Which dimming tech suits which job? Trailing edge, 1–10 V, DALI, PWM and wireless compared, plus cabling, common mistakes and a dimmer load example.

Lighting design for the whole house: room by room in 6 steps

Lighting design for a house: lux values for every room in one table, the process in 6 steps, a worked example and the mistakes that cost money later.

Lux, Lumens and Candela: The Difference, Simply Explained

Lumens, candela and lux explained in one table: what a luminaire emits, how tightly it beams and what reaches the surface. With a beam angle calculation.

Lightbuilder

Lighting design software nobody needs to explain

Lighting design software electricians can use right away: upload a floor plan, place luminaires, check lux per room. €49.90 net/month, cancel monthly.

DIALux alternative: lighting design without the learning curve

Looking for a simple DIALux alternative? Lightbuilder lets electricians create a lighting plan PDF in minutes — £0 training needed, €49.90 net/month.

Relux alternative: lighting design without the learning curve

Relux is great for normative verification — but slow for quick quotes. The fair comparison: when you need simulation, and when Lightbuilder does the job.

Free lighting design software: the honest overview

Which lighting design software is truly free — and what does it cost in time? Pro simulation, free tools and Lightbuilder compared for electricians.

Lighting design software: create your own lighting plan in minutes

Lighting design software in your browser: upload a floor plan, place luminaires, check lux per room, export a PDF lighting plan. €49.90 net/month.

Online lighting design — straight in your browser, no installation

Online lighting design for electricians: upload a floor plan, place luminaires, check lux per room and export a PDF — all in your browser, EU servers.

Lighting calculation software that calculates as you place

Lighting calculation software for electricians: lux per room plus a live heatmap as you place luminaires. Formula, worked example and EN 12464-1 targets.

How many lux does each room need? The chart for everyday jobs

Lux levels chart for every room type: office, workshop, warehouse, retail and homes. EN 12464-1 guide values plus rule-of-thumb formulas for site work.

Office lighting design: standards, common mistakes and a worked example

Office lighting design to EN 12464-1: 500 lux, UGR ≤ 19, colour temperature — plus a worked example and the 5 most common mistakes electricians make.

How to Create a Lighting Plan: The 5-Step Guide

Create a lighting plan yourself: upload a floor plan, set the scale, check rooms, place luminaires, export a PDF. A step-by-step guide with practical tips.

Lighting design for electricians: from floor plan to lighting plan in minutes

Lighting design for electricians: upload a floor plan, place luminaires, check lux, get a PDF lighting plan with parts list. €49.90 net/month, 5 projects.

Lighting design for planners and architects: a lighting concept at concept stage

Lighting design for architects: upload a floor plan, place luminaires, check lux levels and export a PDF for clients. In the browser, no training needed.

Lighting design for interior fit-outs and kitchen showrooms: plan the lighting from day one

Lighting design for interior fit-outs, kitchen showrooms and shopfitting: upload a floor plan, place furniture and lights, export a PDF lighting plan.

Lighting Design Software Compared: Which Suits Which Project?

Lighting design software compared: simulation tools, room planners or planning in the browser. Learning curve, lux check, output and cost reviewed.

Check the layout instead of guessing

Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.