Restaurant lighting design: atmosphere out front, task lighting at the back
Hospitality means lighting design in two halves: out front, atmosphere in the dining room sells the second drink; at the back, the kitchen has to meet workplace lighting levels just like a workshop. If you plan both worlds separately — and treat the bar as the stage in between — you deliver a concept, not just a luminaire list.
Guide values: zones in a restaurant
Guide values based on EN 12464-1 (kitchen) and hospitality practice (dining room):
| Zone | Guide value |
|---|---|
| Dining room, evening | 100–200 lx, dimmable |
| Table surface (pool of light) | 200 lx on the table |
| Bar / counter | 300 lx work surface + accent |
| Buffet / food service counter | 500 lx, Ra ≥ 90 |
| Commercial kitchen | 500 lx |
| Colour temperature, dining room | 2,200–2,700 K |
The golden rule in the dining room: put light on the tables, not into the room. Pendants 60–70 cm above the tabletop create private pools of light — the space in between can and should stay darker. As a bonus, that cuts the luminaire count significantly.
The kitchen, on the other hand, is a workplace governed by the standard: 500 lx, 4,000 K, IP-rated luminaires for damp conditions above the work zones. The transition (pass, service counter) needs an intermediate level so plates look true to colour during plating — Ra ≥ 90 really pays off here.
Worked example: restaurant 100 m², 40 covers
Dining room 80 m² with 12 tables and a 6 m bar, kitchen 20 m². Ceiling 3 m, style: upmarket rustic.
Dining room: 12 tables × ~600 lm pendant + ambient light ≈ 12,000 lm
Dining room: one pendant per table (500–700 lm, 2,500 K, dimmable) plus restrained ambient light from wall lights and a few downlights in the circulation zones (around 5,000 lm in total). The bar gets its own lighting axis: spotlights on the front (the stage), task lighting behind the counter.
Kitchen: 20 m² × 500 lx ÷ 0.6 ≈ 17,000 lm — so 3 IP65 batten luminaires at 6,000 lm each (4,000 K). Striking but typical: the small kitchen needs more lumens than the entire dining room.
The 4 most common mistakes in restaurant lighting
Uniformly bright dining room. An even 300 lx turns a restaurant into a canteen. Light belongs on tables, bar and walls — the space in between lives off restraint.
No dimming, or the wrong kind. Lunch trade, dusk and evening service all need different scenes. Without dimming (ideally scene-based), even the best concept falls flat — plan for DALI, or at least phase dimming per zone.
Kitchen lit like the dining room. 2,700 K and open spotlights have no place in a commercial kitchen: there it's 500 lx, 4,000 K, IP protection and easy maintenance. Two worlds, two sections on the bill of materials.
Food under poor colour rendering. At Ra 80 the steak looks grey and the salad dull. Wherever food is presented (table, buffet, counter), specify Ra ≥ 90.
Check the layout instead of guessing
Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.
Frequently asked questions
- How many lux does a restaurant need?
- In the dining room, 100–200 lx in the evening with 200 lx targeted on the tables — far less than in workspaces. Bar 300 lx, commercial kitchen 500 lx.
- Which colour temperature for the dining room?
- 2,200–2,700 K for upmarket evening dining, 3,000 K for café and lunchtime trade. Cool white belongs only in the kitchen (4,000 K).
- How high should pendants hang above restaurant tables?
- 60–70 cm above the tabletop — low enough for the pool-of-light effect, high enough for a clear line of sight. One pendant with 500–700 lm per table is usually enough.
- What applies in a commercial kitchen?
- Workplace levels: 500 lx, 4,000 K, luminaires rated for damp conditions (IP54/65), easy to clean. Above the prep area and the pass, add good colour rendering (Ra ≥ 90).
Read on
All lux figures are guide values based on EN 12464-1 or common practice — a planning aid, not a normative proof. Professional review and execution remain the responsibility of the contractor.