Guide · Lighting design by room
Bathroom lighting design: brightness, IP zones and the mirror
In the bathroom, two planning worlds meet: lighting (the mirror is the most important task area in the whole home) and electrical safety (IP protection zones around the shower and bath). Keep the two cleanly separated and you can plan a bathroom in ten minutes.
Guide values: light levels and IP ratings in the bathroom
The practical brightness values plus the protection zones to IEC/HD 60364-7-701:
| Area | Guide value |
|---|---|
| General bathroom lighting | 200–300 lx |
| Mirror/grooming area (vertical, onto the face) | 500 lx |
| Shower / bath | 200 lx |
| Zone 0 (inside the bath/shower) | IPX7, max. 12 V |
| Zone 1 (above bath/shower up to 2.25 m) | min. IPX4* |
| Zone 2 (60 cm around zone 1) | min. IPX4 |
*In zone 1, additional requirements apply to the power supply — as a qualified contractor you know the details of the national regulations; for the lighting design it means in practice: above the shower and bath, only fit luminaires with the appropriate IP rating and state it clearly in the parts list.
The mirror lighting is where good bathroom design separates itself from bad: light must fall onto the face from the front — ideally two vertical luminaires either side of the mirror or an illuminated mirror. A downlight above the head creates shadows under the eyes and chin.
Worked example: 8 m² bathroom with shower
Bathroom 3.2 × 2.5 m, ceiling 2.4 m, level-access shower in the corner, double washbasin with mirror. Target: 250 lx general lighting, a bright mirror area.
8 m² × 250 lx ÷ 0.7 ≈ 2,900 lm
The factor of 0.7 is generous in a bathroom (light tiles reflect well). 4 downlights at 700–800 lm each (IP44) cover it — one of them in the shower rated IP65. Layout: one each in front of the shower and WC, two in the central area.
At the mirror: two vertical luminaires or an LED mirror with around 1,500 lm in total, 3,000–4,000 K, Ra ≥ 90. Switched separately — at night, dimmed general lighting is enough; in the morning, only the mirror area runs at full brightness.
The 4 most common bathroom lighting mistakes
Downlight above the mirror instead of light from the front. Light from above accentuates dark circles and beard shadows. For the face, light must come from the front: side-mounted mirror luminaires or an illuminated mirror — the downlight above is only a supplement.
IP protection ignored across the board or overdone. Zone 1 needs at least IPX4 (in practice: IP65 downlights), IP44 is enough for the rest of the bathroom — and outside the zones, formally even less. Specify everything in IP65 and you waste budget; ignore the zones and you risk failing the inspection.
One lighting scene for everything. Full brightness at 3 a.m. is an imposition. Switch the mirror area and general lighting separately, make the general lighting dimmable or provide a night light — a small detail, big customer satisfaction.
Cold light in a relaxing bathroom. 6,500 K makes a bathroom feel like a lab. Use 3,000 K as the base, up to 4,000 K at the mirror for neutral colours — what matters is a consistent colour temperature within each field of view.
Check the layout instead of guessing
Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.
Frequently asked questions
- How many lux does a bathroom need?
- General lighting 200–300 lx, at the mirror 500 lx vertical onto the face. For an 8 m² bathroom that works out at around 3,000 lm of general lighting plus roughly 1,500 lm at the mirror area.
- What IP rating do bathroom luminaires need?
- In zone 1 (above the shower/bath) at least IPX4; IP65 downlights are the norm. In the rest of the bathroom, IP44 has established itself as standard. In zone 0, only special solutions with separated extra-low voltage are permitted.
- What lighting should go at the bathroom mirror?
- From the front, symmetrical, glare-free: two vertical luminaires at the sides or an illuminated mirror. 3,000–4,000 K and Ra ≥ 90, around 1,500 lm in total for the washbasin area.
- Can a downlight go in the shower?
- Yes, with the appropriate IP rating (zone 1: IP65 in practice) and a compliant power supply. That is exactly why you state the IP rating for each luminaire in the parts list.
Read on
All lux figures are guide values based on EN 12464-1 or common practice — a planning aid, not a normative proof. Professional review and execution remain the responsibility of the contractor.