Guide · Lighting design by room

Bedroom lighting design: soft ambient light, bright where it matters

In the bedroom, less is almost always more — with two exceptions: reading light at the bed and light in the wardrobe. If you separate these three layers (soft ambient light, targeted reading light, functional wardrobe light), you turn the most underrated room in the house into a selling point.

Guide values: zones in the bedroom

Practical guide values for domestic bedrooms:

ZoneGuide value
Ambient lighting100 lx
Reading area at the bed300 lx (localised)
Wardrobe / dressing area300 lx vertical
Colour temperature2,700 K, 4,000 K for dressing
Dimmable ambient lightstrongly recommended
Night-time orientation< 10 lx, at floor level

Ambient light looks best when it comes indirectly: wall washers, a ceiling light with a soft diffuser or an LED strip on top of the wardrobe aimed at the ceiling. Direct downlights above the bed are the classic mistake — you lie down and stare straight into them.

At the wardrobe, vertical illuminance is what counts: the light needs to fall into the wardrobe or onto its front. One or two downlights roughly 50–70 cm in front of the wardrobe doors, or integrated wardrobe lighting, will sort this.

Worked example: 14 m² bedroom

Room 4 × 3.5 m, double bed against the wall, fitted wardrobe opposite, ceiling height 2.5 m.

14 m² × 100 lx ÷ 0.6 ≈ 2,300 lm ambient light

Ambient light: 3 downlights at 700 lm each (2,700 K, dimmable) — one in front of the wardrobe, two in the walkway, none above the bed. Alternatively, an indirect ceiling solution delivering a similar luminous flux.

Add two reading lights at the headboard (300–400 lm each, adjustable, individually switched per side of the bed) and optionally a floor-level night light with a motion sensor towards the bathroom — three small items that make more of an impression on the quote than any extra downlight.

The 4 most common bedroom lighting mistakes

  1. Downlights above the bed. Lying down is the main viewing position in this room. Direct spotlights belong in the walkway and in front of the wardrobe — never above the pillows.

  2. Reading light on the main switch. If the reading light only switches with the room lighting, it's useless. Plan a separate light with its own switch (or a switch by the bed) for each side of the bed.

  3. Wardrobe with no light. Telling clothing colours apart in the morning under 100 lx of ambient light simply doesn't work. Fit downlights in front of the wardrobe doors or internal wardrobe lighting — at 4,000 K for true colours.

  4. Cool white as the default. In the bedroom, cool light noticeably disrupts the evening wind-down. Use 2,700 K as the baseline; neutral white only where needed at the wardrobe or as a second channel (tunable white).

Check the layout instead of guessing

Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.

Frequently asked questions

How many lux does a bedroom need?
100 lx of ambient lighting is enough. More in specific spots: 300 lx at the reading area and in front of the wardrobe. Dimmability and a warm colour temperature matter more than brightness.
What colour temperature for a bedroom?
2,700 K (extra warm white) for the ambient light. At the wardrobe or dressing table, 4,000 K works well for neutral colour rendering — as a separately switched zone.
What reading light should I fit at the bed?
Adjustable wall lights or bedside lights with 300–400 lm per side, glare-free for your partner, individually switched. A narrow beam angle keeps the light on the book.
Downlights in the bedroom — yes or no?
Yes, but only in walkways and in front of the wardrobe, dimmable and warm white. Above the bed itself, go for indirect light instead.

Read on

All lux figures are guide values based on EN 12464-1 or common practice — a planning aid, not a normative proof. Professional review and execution remain the responsibility of the contractor.