Guide · Lighting design by room
Lighting design for hallways and entrance halls: the underrated first impression
The hallway is the first room every guest sees — and the last one anyone budgets for. Yet it’s a grateful space to plan: narrow geometry, a clear direction of travel, two functional points (coat rack, mirror). With the right spacing rule, the design is sorted in five minutes.
Guide values: hallway, entrance hall, entrance area
The practical guide values for domestic circulation areas:
| Area | Guide value |
|---|---|
| Hallway / entrance hall ambient light | 100 lx |
| Entrance area (indoors) | 150 lx |
| Coat rack / mirror | 300 lx (vertical) |
| Night-light function | < 10 lx, dimmed/low-level |
| Colour temperature | 2,700–3,000 K |
| Downlight spacing in the hallway | 1.2–1.5 m (with a 2.5 m ceiling) |
In a narrow hallway, it’s the lengthwise spacing that counts: downlights centred in a single row — going beyond roughly 1.2 to 1.5 times that spacing would create dark troughs between the light cones. Rule of thumb: spacing ≈ half to the full ceiling height, starting at half the spacing from the end walls.
The coat rack and mirror are mini task areas: the mirror needs — just as in the bathroom — light on the face from the front, while the coat rack needs vertical light on the jackets. An extra downlight around 50 cm in front of the mirror or wardrobe front solves both.
Worked example: hallway 8 m long, 1.4 m wide
Long flat hallway, 8 × 1.4 m (11 m²), 2.5 m ceiling, coat rack and mirror near the front door.
11 m² × 100 lx ÷ 0.6 ≈ 1,900 lm — spread across 5–6 points
5–6 downlights at 350–450 lm each, centred in a single row, spaced roughly 1.4 m apart, with half that spacing to the end walls. Deliberately many small points rather than three big ones: in a hallway, uniformity beats raw lumen output.
An extra downlight in front of the coat rack/mirror (this point can be brighter — 300 lx vertical). One circuit, ideally with a dimmer or a separate night light: at night, a fraction of the brightness is enough for the route to the bathroom.
The 4 most common hallway lighting mistakes
Spacing too wide. Three downlights over eight metres create a string of light cones with dark troughs in between. Base the spacing on the ceiling height (with 2.5 m: roughly 1.2–1.5 m) — better to use more small points.
Mirror lit from above. A downlight directly above the mirror lights up the top of the head, not the face. Position the fitting 40–60 cm in front of the mirror — the light then falls from the front at an angle.
Cool light in a residential hallway. The hallway connects living spaces lit at 2,700 K — a 4,000 K hallway in between feels like a corridor in a government office. Match the colour temperature to the adjoining rooms.
No night-time concept. A full 100 lx at 3 a.m. is needlessly bright. A dimmable circuit, a low-level orientation light or a sensor with night mode — a small line item, a noticeable gain in comfort.
Check the layout instead of guessing
Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.
Frequently asked questions
- How many lux does a hallway need?
- 100 lx of ambient lighting, 150 lx in the entrance area, and 300 lx locally at the coat rack and mirror. More important than brightness: even spacing with no dark zones.
- What spacing between downlights in a hallway?
- Rule of thumb for a 2.5 m ceiling: 1.2–1.5 m spacing in a centred row, starting at half that spacing from the end walls. You’ll find the details and formula in our downlight spacing guide.
- How many downlights for an 8 m hallway?
- 5–6 units at 350–450 lm each. More small light points beat a few big ones — a hallway lives on uniformity, not peak brightness.
- What colour temperature for a hallway?
- 2,700–3,000 K, to match the adjoining living spaces. Neutral white only in purely functional corridors (basement, utility areas).
Read on
All lux figures are guide values based on EN 12464-1 or common practice — a planning aid, not a normative proof. Professional review and execution remain the responsibility of the contractor.