Guide · Lighting design by room
Stairwell lighting design: safe, sensor-controlled, low maintenance
The stairwell is the space with the clearest safety brief: step edges must be recognisable as edges — falls on stairs are the most common accident in the home. At the same time, it offers the biggest savings potential in a block of flats, because otherwise the lights burn for hours with nobody there.
Guide values: stairwell and entrances
Guide values based on EN 12464-1:
| Area | Guide value |
|---|---|
| Stair flights and landings | 100–150 lx |
| Main entrance / letterboxes | 200 lx |
| Basement stairs | 100 lx |
| Uniformity on the stairs | as high as possible, no harsh shadows |
| Colour temperature | 3,000–4,000 K |
| Control | presence detector per floor, 2–5 min run-on time |
Luminaire position determines how well the steps read: light should fall onto the stairs at an angle from above, so every step gets a visible, soft shadow edge. A luminaire directly over the stairwell void or facing the stairs head-on flattens the edges visually.
For control, networked presence detectors on each floor are the standard today: the light runs ahead of the person (the adjacent floor switches on too) instead of the whole building being lit. Compared with the classic stairwell timer switch, that saves 60–80 % in energy.
Worked example: block of flats, 4 storeys
Dog-leg staircase with half landing, floor landings approx. 6 m², ceiling height 2.6 m per storey.
Per storey: 1 luminaire on the floor landing + 1 luminaire on the half landing at 1,000–1,500 lm each
Two wall or ceiling luminaires per storey at approx. 1,200 lm each (IP20 is sufficient indoors; choose a robust build because of vandalism in communal blocks) — positioned so both flights are lit at an angle. Result: 100–150 lx on all flights, no dark turning points.
Add the main entrance at 200 lx (its own detector, dusk switching) and the basement stairs with a dedicated luminaire. For 4 storeys: approx. 10 luminaires + 5 detectors — as a refurbishment, this usually pays for itself through the communal electricity bill within 2–3 years.
The 4 most common stairwell lighting mistakes
Luminaire facing the stairs head-on. Frontal light wipes out the shadow edges of the steps — the staircase reads like a ramp. Position luminaires offset to the side or above the landings, so light falls across the flights at an angle.
Timer switch instead of detectors. The classic stairwell timer switches the whole building and cuts out halfway up the stairs. Presence detectors per floor with run-on time and floor-to-floor logic are safer and more economical.
Dark half landing. Half landings often sit in the blind spot of the floor luminaire. On dog-leg staircases, every half landing needs its own luminaire.
Maintenance not considered. Nobody volunteers to change a luminaire hanging 8 m up in the stairwell void. Choose positions that can be reached from a landing or a ladder — and use long-life LED luminaires (L80 ≥ 50,000 h).
Check the layout instead of guessing
Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.
Frequently asked questions
- How many lux does a stairwell need?
- 100–150 lx on flights and landings, 200 lx at the main entrance. More important than the absolute value: even illumination without harsh shadows and clearly visible step edges.
- Presence detectors or a stairwell timer switch?
- Detectors per floor: light only where someone is, no sudden darkness halfway up the stairs, 60–80 % savings. The timer switch only makes sense for minimal refurbishments.
- Does a stairwell need emergency lighting?
- In standard residential buildings it is not mandatory; in special building types (high-rise buildings, accommodation, assembly venues) it is. When in doubt, the building regulations applicable to the property apply — as a professional contractor, you flag this in your quotation.
- Which luminaires for a stairwell in a block of flats?
- Robust wall/ceiling luminaires with an opal diffuser (low glare), 1,000–1,500 lm, 3,000–4,000 K, with an integrated or external detector. In rougher buildings, choose an impact-resistant version (IK rating).
Read on
All lux figures are guide values based on EN 12464-1 or common practice — a planning aid, not a normative proof. Professional review and execution remain the responsibility of the contractor.