Planning LED Strips: Getting Lumens per Metre, Profile and Driver Right
LED strips are the most flexible light source in residential work: under the wall units, in the coving, along the plinth, on the stairs. They are also the light where most things go wrong, because three things have to match: the brightness per metre, the profile and the driver. The table shows you which light output suits which job. Then we work through a driver calculation.
Table: How Many Lumens per Metre for Which Application?
Practical guide values for the luminous flux per linear metre. They apply to strips in an aluminium profile with a diffuser, which absorbs 10 to 30 % of the light depending on the type:
| Application | Luminous flux per metre |
|---|---|
| Plinth and orientation lighting | 200–500 lm/m |
| Stair treads, handrail | 200–400 lm/m |
| Accent lighting in shelving, display cabinet, headboard | 400–800 lm/m |
| Indirect light in coving or ceiling recess | 800–1,500 lm/m |
| Task lighting under the wall units | 1,000–1,500 lm/m |
| Mirror lighting in the bathroom | 1,000–1,500 lm/m |
| Linear light as the main light (profile recessed in the ceiling) | 1,500–2,500 lm/m |
COB or SMD? On an SMD strip, individual LEDs sit spaced out along the tape; on a COB strip, a continuous phosphor layer covers them. COB gives you an unbroken line with no visible dots, even in shallow profiles and when the strip reflects in a glossy worktop. SMD is fine when the strip is concealed and only its light is visible, for example in a deep cove.
The aluminium profile is not an accessory — it is part of the luminaire. It dissipates the heat and therefore determines the lifespan, it protects the strip, and it carries the diffuser that turns dots into a line. Rule of thumb: from around 10 W per metre, every strip belongs in a profile; anywhere it is visible, always.
24 volts instead of 12 volts: at the same power, half the current flows, the voltage drop is smaller and the runs can be longer. Up to 5 m per feed is typical, with some 24 V types up to 10 m. The datasheet is always the deciding factor. Feed longer runs from both ends or in the middle, otherwise the far end becomes visibly dimmer.
Colour temperature and colour rendering: in the kitchen and at the mirror, a strip with CRI 90 or higher is worth it, because food and skin otherwise look washed out. If you want mood lighting and task lighting from the same profile, choose a strip with tunable white (2,700 to 6,500 K) and plan the matching controller from the start.
Worked Example: Driver for the Kitchen Run
Under-cabinet lighting along 4.2 m of worktop plus 2.3 m of plinth lighting on the island — 6.5 m of strip in total at 14.4 W per metre on 24 V.
6.5 m × 14.4 W/m = 93.6 W → + 20 % headroom = 112 W → 120 W driver
The 20 % headroom is not caution out of habit: a driver running at its load limit gets hot, ages faster and is more likely to flicker when dimmed. Always calculate the headroom on the actual strip wattage, not on the nominal length of the reel.
Two runs, two jobs: task lighting and plinth lighting belong on separate outputs or separate drivers. That way, the plinth light can be switched on its own in the evening. Plan the space for the driver too — accessible and ventilated, for example in a wall unit or in the plinth.
The 5 Most Common Mistakes with LED Strips
Strip stuck down without a profile. Stuck directly onto wood or plaster, the heat builds up. The strip visibly loses brightness after months, individual sections discolour, the adhesive lets go. The profile costs little and prevents all three problems.
Driver with no headroom. 93 W of strip on a 100 W driver works, but not well for long. Allow 20 % headroom and check that the driver matches the dimming method.
Runs too long, fed from one side only. At the end of an overlong run, less voltage arrives — the light gets dimmer and warmer in tone. Stick to the maximum length in the datasheet and add a new feed in good time.
Visible light dots. A shallow profile, a clear diffuser and an SMD strip with few LEDs per metre add up to a string of beads. The fix: a COB strip, an opal diffuser or a deeper profile.
Wrong IP rating in the bathroom and outdoors. An open IP20 strip does not belong in the shower or under the porch roof. In splash zones at least IP44, with direct water jets and outdoors IP65 or higher — always together with a suitable profile and observing the bathroom zones to IEC/HD 60364-7-701.
Check the layout instead of guessing
Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.
Frequently asked questions
- How many lumens per metre does an LED strip need?
- It depends on the job: 200–500 lm/m for plinth and orientation lighting, 800–1,500 lm/m for indirect light and task lighting under the wall units, 1,500–2,500 lm/m if the linear light is to be the main light in the room.
- How do I size the driver for an LED strip?
- Length in metres × watts per metre, plus 20 % headroom. Example: 5 m × 9.6 W/m = 48 W, with headroom 58 W, so a 60 W driver. The driver voltage (12 V or 24 V) must match the strip.
- COB or SMD: which is better?
- COB when the strip or its reflection is visible, because it gives a continuous line with no dots. SMD when the strip is concealed. Both are available in warm white, with tunable white and with high colour rendering.
- How long can a single LED strip run be?
- 5 m per feed is typical, with some 24 V strips up to 10 m. Beyond that, the voltage drops too much. Longer runs are fed from both ends or in the middle.
- Does an LED strip count in the lux calculation?
- Yes. Calculate with the lumens per metre times the length. With indirect lighting, only part of it reaches the room because it is first reflected off the ceiling or wall — with light-coloured surfaces roughly half to two thirds. In Lightbuilder you draw the strip as a line on the plan and see its contribution in the lux check as a rough calculation.
Read on
All lux figures are guide values based on EN 12464-1 or common practice — a planning aid, not a normative proof. Professional review and execution remain the responsibility of the contractor.