Guide · Lighting know-how
Lux, Lumens and Candela: The Difference, Simply Explained
Three units that constantly get mixed up, and each one answers a different question. Lumens tell you how much light a luminaire emits in total. Candela tells you how tightly it focuses that light in one direction. Lux tells you how much of it actually reaches a surface. For lighting design, lux is what counts in the end, but you can't get there without the other two.
Table: The Key Lighting Quantities at a Glance
You'll find these figures on datasheets and packaging. For lighting design, the first three are the ones that matter most:
| Quantity (unit) | What it tells you |
|---|---|
| Luminous flux (lumens, lm) | Total amount of light a luminaire emits, in all directions combined |
| Luminous intensity (candela, cd) | Light in a specific direction; high with a narrow beam angle |
| Illuminance (lux, lx) | Light arriving on a surface; 1 lx = 1 lm per m² |
| Luminous efficacy (lm/W) | Efficiency: how much light you get from one watt of power |
| Colour temperature (kelvin, K) | Light colour from warm white (2,700 K) to daylight white (6,500 K) |
| Colour rendering (Ra / CRI) | How natural colours appear; Ra 80 and above is good, Ra 90 and above is excellent |
| Glare (UGR) | How much glare an installation produces; no more than 19 in offices |
Lumens are the figure you use to compare luminaires. They've replaced wattage, because watts only tell you the consumption. Depending on quality, a 7 W LED delivers 500 or 900 lm.
Candela matters as soon as light is directional. Two spotlights with the same luminous flux can look completely different: the narrow-beam one puts a bright spot on a picture, while the wide-beam one spreads the same light across half the wall. So the beam angle decides where the lumens end up.
Lux is the result of your lighting design. Target values such as 500 lx at an office workstation or 100 lx in a hallway always refer to a surface, usually the working plane or the floor. Lux depends on distance: double the distance and only a quarter of the light arrives. That's why tall rooms need considerably more luminous flux or narrower-beam luminaires.
For a rough calculation across a whole room: lux = lumens × utilisation factor ÷ area. With a utilisation factor of 0.6, you're on the safe side in residential work. For a single spotlight, you calculate using candela and distance, as shown in the example.
Worked Example: Same Luminous Flux, Different Beam Angle
Two spotlights with 600 lm each at a height of 2.5 m, one with a 36° beam angle and one with 24°. For simplicity, we assume all the light falls within the cone.
36°: 600 lm ÷ 0.31 sr ≈ 1,950 cd → 1,950 ÷ 2.5² ≈ 310 lx · 24°: 600 lm ÷ 0.14 sr ≈ 4,370 cd → 4,370 ÷ 2.5² ≈ 700 lx
The same luminous flux produces more than double the illuminance at the centre of the beam, but the illuminated circle on the floor is smaller: around 1.6 m in diameter at 36°, around 1.1 m at 24°. For even general lighting you go for wide angles; for accents and high ceilings, narrow ones.
The calculation is idealised, because real luminaires also emit light outside their rated beam angle. But it shows why the lumen figure alone doesn't tell you how bright it will be at any given spot. In Lightbuilder, you set the beam angle for each luminaire and see the distribution in the lux view as an approximate calculation.
The 4 Most Common Mix-Ups
Treating watts as brightness. Watts measure consumption. Two luminaires rated at 10 W can differ in luminous flux by a factor of two. You compare in lumens.
Confusing lumens with lux. There's no such thing as ‘the luminaire has 3,000 lux’ without stating distance and area. The luminaire has lumens; the room gets lux.
Ignoring the beam angle. If you order by lumens alone, narrow spotlights will give you bright patches with dark zones in between. Beam angle and luminaire spacing go hand in hand.
Not accounting for ceiling height. The number of fittings that works in a living room with a 2.5 m ceiling won't do for a double-height space at 5 m. Illuminance drops with the square of the distance as height increases.
Check the layout instead of guessing
Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.
Frequently asked questions
- How do I convert lumens to lux?
- Lux = lumens ÷ area in m². For a room, add the utilisation factor: lux ≈ lumens × 0.6 ÷ area. Example: 6,000 lm in 20 m² gives around 180 lx.
- How many lux is 1,000 lumens?
- That depends on the area. Over 1 m² it would be 1,000 lx, over 10 m² only 100 lx, and in a room with the utilisation factor around 60 lx.
- What's the difference between lumens and candela?
- Lumens measure the total light from a luminaire, candela the light in one direction. A spotlight with a narrow beam angle has far more candela than an omnidirectional luminaire with the same lumens.
- Which value matters most for lighting design?
- Lux, because all target values refer to it. You need lumens and beam angle to get there.
- How do I measure lux?
- With a lux meter on the surface in question, so on the desk or the worktop. Phone apps only give you a rough indication. Measure without daylight and at several points.
Read on