Guide · Lighting know-how
Lighting design for the whole house: room by room in 6 steps
The lighting design for a house is decided early on, before the cables go in. Leave the lighting until after plastering and you end up with one outlet in the middle of the ceiling and have to live with it. This guide takes you through the whole house: first the recommended values for each room, then the process that turns a floor plan into a design you can show the client and install from.
Table: lux values and luminaires for every room in the house
Tried-and-tested values for residential work. There is no binding standard for domestic rooms; these figures are a planning aid based on EN 12464-1:
| Room | Recommended value and typical solution |
|---|---|
| Living room | 100–150 lx general lighting; downlights around the perimeter, pendant or floor lamp as a pool of light |
| Kitchen | 200 lx general lighting, 500 lx on the worktop; under-cabinet lighting plus ceiling lighting |
| Dining area | 150–200 lx on the table; pendant 60–70 cm above the tabletop |
| Bathroom | 200–300 lx, 500 lx at the mirror; observe the IP rating for each zone to IEC/HD 60364-7-701 |
| Bedroom | 100 lx general lighting; reading light at the bed switched separately |
| Children's room | 150–200 lx; 500 lx at the desk |
| Home office | 300 lx in the room, 500 lx at the workstation |
| Hallway and entrance | 100 lx; even coverage, ideally with a motion sensor |
| Stairs | 100–150 lx; step edges clearly visible, glare-free from above and below |
| Utility room and cellar | 200 lx; robust and neutral white |
| Garage | 100–150 lx; damp-proof luminaires |
Step 1, establish how rooms are used: go through the floor plan with the client room by room. Where will they cook, read, work, watch TV? Where will the sofa, dining table, bed and desk go? The furniture determines the lighting, not the centre of the room.
Step 2, think in three layers: general lighting makes the room bright enough to move around safely. Task lighting goes where the hands are, so on the worktop, the desk and at the mirror. Accent lighting gives the room depth, with wall lights, picture spots or an LED strip. A room with all three layers looks high-end, even with simple luminaires.
Step 3, estimate the quantity: area × target lux ÷ 0.6 gives the lumens required; divide by the luminous flux of the luminaire to get the number of fittings. The factor 0.6 accounts for walls, dirt and ageing.
Step 4, set the positions: start downlights at half the spacing from the wall and align them with furniture and walkways. Pendants hang above the dining table and the kitchen island, not in a grid. Nothing goes in the swing path of doors or in front of tall cupboards.
Step 5, create switching groups: each layer gets its own group. In the living and dining area, three to four separately switched or dimmable groups are standard. Switches belong at every entrance, and at the top and bottom of the stairs.
Step 6, check and document: check for each room whether the target value is met, and record positions, luminaire types and groups in a plan with a parts list. This plan is the basis for your quote and for the cable routes at first fix.
Worked example: ground floor with open-plan living area
Living and dining 38 m² at 150 lx, kitchen 14 m² at 200 lx general lighting, hallway 9 m² at 100 lx. Downlights with 700 lm.
Living/dining: 38 × 150 ÷ 0.6 = 9,500 lm · Kitchen: 14 × 200 ÷ 0.6 ≈ 4,700 lm · Hallway: 9 × 100 ÷ 0.6 = 1,500 lm
In the living and dining area that would mean 14 downlights. In practice, a pendant above the dining table with around 2,000 lm covers part of it, and a floor lamp by the sofa another part. That leaves 8 to 9 downlights, spread across the walkway and wall areas. The result feels more homely than a grid and needs fewer outlets.
The kitchen reaches its general lighting level with 7 downlights, with the task lighting under the wall cabinets on top. In the hallway, 4 smaller downlights at 400 lm are enough. Three short calculations produce the parts list for an entire floor.
The 5 most expensive mistakes in house lighting design
Planning too late. After first fix, almost nothing can be moved. Lighting design belongs before the electrical design, at the latest alongside the kitchen design.
One outlet in the middle of the room. The centre is the spot where something is least likely to stand. Light belongs above the table, the worktop and on the walls.
Ignoring the furniture. The pendant outlet ends up 40 cm off the dining table, the downlight above the wardrobe. Furniture goes into the plan first, then the luminaires.
Too few switching groups. Everything on one switch saves one cable during the build and annoys the client for years. Separate groups are the cheapest route to good lighting.
Forgetting the stairs and outdoor areas. Stairs are the most common accident spot in the house, and the front entrance is its calling card. Plan both in early and allow for cables to the outside from the start.
Check the layout instead of guessing
Whether the values really arrive on the surface only shows in the plan, not in the rule of thumb. In Lightbuilder you upload the floor plan, place the luminaires step by step and see for every room whether it is bright enough — as an approximate calculation, made for electrical contractors.
Frequently asked questions
- When should the lighting design for a new build be finished?
- Before the electrical first fix. The ideal point is when the floor plan is fixed and the kitchen is being designed, because that is when furniture and worktops are known.
- How many luminaires does a family house need?
- As a rough figure, 50 to 90 lighting points for 140 m² of living space, depending on how much is covered by downlights and how much by pendants, wall lights and floor lamps. The room-by-room calculation gives you a more accurate answer.
- How much does a lighting design for a house cost?
- A design consultancy usually charges by time or per square metre, easily several hundred to over a thousand euros for a detached house. Many electrical contractors produce the lighting plan themselves and offer it together with the installation.
- Which colour temperature suits a home?
- Living rooms and bedrooms 2,700 K, kitchen and bathroom 3,000 K, utility room, cellar and garage 4,000 K. Stick to one colour temperature within a room.
- Can I do the lighting design for a house myself?
- For homes, yes. In Lightbuilder you upload the floor plan, set the scale, draw in the rooms and place the luminaires. The lux check shows for each room whether the target value is met. It is an approximate calculation intended as a planning aid and does not replace a detailed lighting design with normative verification.
Read on
All lux figures are guide values based on EN 12464-1 or common practice — a planning aid, not a normative proof. Professional review and execution remain the responsibility of the contractor.